- Flexibility: Two or four RS-232 or RS-422/485 serial ports
- Protection: Ports are individually optically isolated at 3.0 kV AC* (most models) peak to peak
- Speed: Data rates up to 460.8 Kbps
- Performance: Ports controlled by a high performance dual UART, which is backward compatible with standard 16450 and 16550 UARTs.
- Adaptability: Support for three RS-485 modes: full duplex, half duplex and multi-drop
Xtreme/104 Opto – PC/104 Serial
More Information
Compact yet powerful, the Xtreme/104 Opto PC/104 serial card performs where others fail. Durable and stackable, Xtreme/104 Opto’s small PC/104 form factor makes it the ideal serial communications link in today’s demanding embedded systems.
Xtreme/104 Opto offers 3 kV optical isolation on all signals and ports to ensure smooth, error-free transmission of data even in the noisiest environments. With the added feature of industrial temperature range operation, this PC/104 serial card is well suited to any embedded computer system that is exposed to harsh conditions.
Based on the 16C2850 UART with 128 byte transmit and receive FIFO buffers, Xtreme/104 Opto provides rapid data communications for your military, aerospace, medical, transportation and industrial automation applications.
Specifications
Ports | 2 or 4 ports |
---|---|
Electrical Interfaces | Each port is jumper selectable, RS-232, RS-422/485 |
Connectors | 10-pin header connectors |
Control Signals | RS-232: TxD, RxD, RTS, CTS, RS-422/485: TxD+/-, RxD+/-, RTS+/-, CTS+/- |
Baud Rate | RS-232: 50 bps – 230.4 Kbps, RS-422/485: 50 bps – 460.8 Kbps |
Interrupts | Jumper selectable for IRQs 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14, 15 |
I/O Addresses | Eight pre-defined sets of I/O addresses are jumper selectable |
Dimensions | 96mm x 104.1mm x 11.2mm (3.77" x 4.09" x 0.44") |
Operating Temperature | -40°C to +85°C (-40°F to +185°F), 0°C to +70°C (+32°F to +158°F) |
Storage Temperature | -40°C to +150°C (-40°F to +302°F) |
Humidity | 95% non-condensing |
Bus | ISA bus compatible, 16-bit PC/104 connector |
Operating System | DOS, Linux, QNX, SCO Unix, Solaris, VxWorks, Windows |
Optical Isolation | Each port is isolated up to 3 kV AC peak, 3.0 kV DC and 2.1 kV AC |
System Interfaces | One available PC/104 module stack connector |
Power Requirements | +5V DC @ 260mA (typ) |
Downloads for Xtreme/104 Opto – 1040290200
Drivers for Xtreme/104
Operating System | Driver Information | Resources |
---|---|---|
Windows 10, Windows 8, Windows 8 64-bit, Windows 7, Windows 7 64-Bit, Windows Vista, Windows Server 2008 64-Bit, Windows Server 2003, Windows XP, Windows XP Embedded, Windows 2000 | Name: XT-WIN_2016.zip Version: 2.0.1.6 Released: 02.26.2013 |
Download Driver Install Guide (XP+) Install Guide (2000) Install Guide (XP+) Install Guide (XP Embedded) |
Windows 95/98/Me | Name: EC-98_149.zip Version: 1.49 Released: 09.22.2005 |
Download Driver Install Guide |
Windows CE 6.0, Windows CE .NET, Windows CE 3.0 | Name: DF-CE_102.zip Version: 1.02 Released: 11.20.2002 |
Download Driver Install Guide (CE 6.0) Install Guide (CE 3.0/CE.NET) |
Windows NT | Name: Standard Serial Driver Version: n/a Released: n/a |
Driver Provided with OS Install Guide |
Linux (3.9.x +) | Name: cti_serial_144.tgz Version: 1.44 Released: 06.23.2020 |
Request Driver Install Guide |
Linux (2.6.39, 3.8.x) | Name: cti_serial_125a.tgz Version: 1.25 Released: 08.11.2014 |
Request Driver Install Guide |
Linux (2.6.18 to 2.6.38) | Name: cti_serial_113a-2.6.38.tgz Version: 1.13a-2.6.38 Released: 08.11.2014 |
Request Driver Install Guide |
Linux 2.4 | Name: ctix-24-1.00.tar.gz Version: 1.00 Released: 10.11.2007 |
Download Driver Install Guide |
QNX 6 (Neutrino) | Name: Standard Serial Driver Version: n/a Released: n/a |
Driver provided with OS Install Guide |
QNX 4 | Name: DF-Q4_425e.tar Version: 14.25e Released: 03.17.2003 |
Download Driver Install Guide |
QNX 2 | Name: Standard Serial Driver Version: n/a Released: n/a |
Driver provided with OS Installation guide not available |
Solaris 8 | Name: Standard Serial Driver Version: n/a Released: n/a |
Driver provided with OS Install Guide |
DOS | Name: DF-DOS_105.zip Version: 1.05 Released: 08.19.1996 |
Download Driver Installation guide not available |
SCO Unix/Openserver | Name: DF-SCO_220.tar Version: 2.20 Released: 10.07.1999 |
Download Driver Install Guide |
VxWorks | Name: CTI_SIO_2_0_3_0.zip Version: 2.0.3.0 Released: 09.09.2005 |
Request Driver Install Guide |
Drivers support:
Xtreme/104: 1040490000, 1040490001, 1040490020, 1040490021, 1040890000, 1040890001, 1040890020, 1040890021, XTG490000, XTG490001, XTG490020, XTG490021, XTG890000, XTG890001, XTG890020, XTG890021
Xtreme/104 RS-232: 1040400000, 1040400001, 1040800000, 1040800001, 1040800020, 1040800021, XTG400000, XTG400001, XTG800001, XTG800020, XTG800021
Xtreme/104 Opto: 1040290200, 1040290201, 1040290220, 1040290221, 1040490200, 1040490201, 1040490220, 1040490221, XTG290200, XTG290201, XTG490200, XTG490201, XTG490220, XTG490221
Xtreme/104 Isolated: XT007-01
Comparison Chart
Part Number | Ports | Cables | Features |
---|---|---|---|
1040290200 | 2 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports. |
1040290201 | 2 ports | CAB104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports, and also includes a custom maximum baud rate of 500000 bps. |
1040290220 | 2 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports, and also provides extended temperature protection, with operating ranges between -40°C to +85°C |
1040290221 | 2 ports | CAB104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports, and also provides extended temperature protection, with operating ranges between -40°C to +85°C. |
1040490200 | 4 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports. |
1040490201 | 4 ports | CAB104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports. |
1040490220 | 4 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports, and also provides extended temperature protection with operating ranges between -40°C to +85°C. |
1040490221 | 4 ports | CAB104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports, and also provides extended temperature protection with operating ranges between -40°C to +85°C. |
XTG290200 | 2 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical inerfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak Optical Isolation on all ports. RoHS compliant. |
XTG290201 | 2 ports | CAG104 | This Xtreme/104 offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV AC peak to peak optical isolation on all ports. RoHS compliant. |
XTG490200 | 4 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV peak to peak Optical Isolation on all ports. RoHS compliant. |
XTG490201 | 4 ports | CAG104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV peak to peak Optical Isolation on all ports. RoHS compliant. |
XTG490220 | 4 ports | No Cable | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV peak to peak Optical Isolation on all ports, and also provides extended temperature ranges between -40°C to +85°C. RoHS compliant. |
XTG490221 | 4 ports | CAG104 | This Xtreme/104 Opto offers jumper-selectable electrical interfaces for each port (either RS-232 or RS-422/485), and provides 3.0 kV peak to peak Optical Isolation on all ports, and also provides extended temperature protection with operating ranges between -40°C to +85°C. RoHS compliant. |
Ordering Information
Main Products | |
---|---|
Part Number | Description |
1040290200 | Xtreme/104, 2 ports |
1040290201 | Xtreme/104, 2 ports with CAB104 cable |
1040290220 | Xtreme/104, 2 ports with extended temperature of -40°C to +85°C |
1040290221 | Xtreme/104, 2 ports with extended temperature of -40°C to +85°C and CAB104 cable |
1040490200 | Xtreme/104, 4 ports |
1040490201 | Xtreme/104, 4 ports with CAB104 cable |
1040490220 | Xtreme/104, 4 ports with extended temperature of -40°C to +85°C |
1040490221 | Xtreme/104, 4 ports with extended temperature of -40°C to +85°C and CAB104 cable |
XTG290200 | Xtreme/104, 2 ports and RoHS Compliant |
XTG290201 | Xtreme/104, 2 ports and RoHS Compliant with CAG104 cable |
XTG490200 | Xtreme/104, 4 ports and RoHS Compliant |
XTG490201 | Xtreme/104, 4 ports and RoHS Compliant with CAG104 cable |
XTG490220 | Xtreme/104, 4 ports with extended temperature of -40°C to +85°C and RoHS Compliant |
XTG490221 | Xtreme/104, 4 ports with extended temperature of -40°C to +85°C, RoHS Compliant with CAG104 cable |
Cables/Accessories | |
Part Number | Description |
CAB104 | 1x DB-9 Male, 10-Pin Header |
CAG104 | 1x DB-9 Male, 10-Pin Header, RoHS Compliant |
Custom Design
Looking for a customized PC/104 product? Click here to tell us what you need.